News
News Highlights
- Books
Featured Books
- design007 Magazine
Latest Issues
Current IssueLearning to Speak ‘Fab’
Our expert contributors clear up many of the miscommunication problems between PCB designers and their fab and assembly stakeholders. As you will see, a little extra planning early in the design cycle can go a long way toward maintaining open lines of communication with the fab and assembly folks.
Training New Designers
Where will we find the next generation of PCB designers and design engineers? Once we locate them, how will we train and educate them? What will PCB designers of the future need to master to deal with tomorrow’s technology?
The Designer of the Future
Our expert contributors peer into their crystal balls and offer their thoughts on the designers and design engineers of tomorrow, and what their jobs will look like.
- Articles
- Columns
Search Console
- Links
- Media kit
||| MENU - design007 Magazine
Estimated reading time: 1 minute

Avoid Overload in Gain-Phase Measurements
Today, most of our printed circuit boards have at least a few DC-DC converters, and some boards have many. We have a large choice when it comes to deciding what to use: we can design and build our own converter from discrete parts (called voltage regulator down or VRD) or we can buy one of the off-the-shelf open-frame or fully encapsulated voltage regulator modules (VRM).
For low currents we can use linear regulators; for medium and high current we are better off using a switching-mode topology. Whatever circuit suits best our needs, chances are that we want to keep the output voltage regulated against changes in input voltage and load current, which in turn calls for one or more internal control loops.
There is a well-established theory to design stable control loops, but in the case of power converters, we face a significant challenge: each application may require a different set of output capacitors coming with our loads. Since the regulation feedback loop goes through our bypass capacitors (shown as a single Cout in Fig. 1), our application-dependent set of capacitors now become part of the control feedback loop. Unfortunately, certain combination of output capacitors may cause the converter to become unstable, something we want to avoid. This raises the need to test, measure and/or simulate the control-loop stability.
To read this column, which appeared in the June 2015 issue of The PCB Design Magazine, click here.
More Columns from Quiet Power
Quiet Power: An Evolution in PCB Design CostsQuiet Power: The Effect on SI and PI Board Performance
Quiet Power: 3D Effects in Power Distribution Networks
Quiet Power: Noise Mitigation in Power Planes
Quiet Power: Uncompensated DC Drop in Power Distribution Networks
Quiet Power: Ask the Experts—PDN Filters
Quiet Power: Friends and Enemies in Power Distribution
Quiet Power: Be Aware of Default Values in Circuit Simulators